MIL-L-11025F
(Applications for copies should be addressed to the American Society of
Mechanical Engineers, 345 East 47th Street, New York, NY 10017.)
AMERICAN WELDING SOCIETY, INC.
(AWS)
D1.1 - Structural Welding Code, Steel.
(Application for copies should be addressed to the American Welding Society,
Inc., 550 NW LeJeune Road, PO Box 351040, Miami, FL 33126.)
(Non-Government standards and other publications are normally available from
the organizations which prepare or which distribute the documents. These
documents also may be available in or through libraries or other informational
services.)
2.3 Order of precedence. In the event of a conflict between the text of this
specification and the references cited herein, (except for associated detail
specifications, specifications sheets or MS standards), the text of this
specification shall take precedence. Nothing in this specification, however,
shall supersede applicable laws and regulations unless a specific exemption has
been obtained.
REQUIREMENTS
3.
3.1 Description. The pile-driver leads shall be in accordance with Top
Assembly TA13207E7680 and as specified herein. The pile-driver leads shall
consist of a top section, one or more lower sections, adapter plates, and a cat-
-
walk assembly. These items may be procured separately, and the items required
shall be as specified (see 6.2).
3.1.1 Drawings. The drawings forming a part of this specification are end
product drawings. No deviation from the prescribed dimensions or tolerances is
permissible without prior approval of the contracting officer. Any data (e.g.,
shop drawings, layouts, flow sheets, processing procedures, etc.) prepared by
the contractor or obtained from a vendor to support fabrication and manufacture
of the production item shall be made available, upon request, for inspection by
the contracting officer or designated representative.
3.2 First article. Unless otherwise specified (see 6.2), a sample shall be
subjected to first article inspection (see 4.3 and 6.3). Any changes or
deviations of pile-driver lead assembly and catwalk assembly from the approved
first article during production will be subject to the approval of the
contracting officer. Approval of the first article will not relieve the
contractor of his obligation to furnish pile-driver lead assembly and catwalk
assembly conforming to this specification.
Material shall be as specified herein and on the applicable
3.3 Material.
drawings.
3.4 Lead sections.
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business